Secure Power Solutions
Critical operations demand clean, stable, and uninterrupted power supply. Voltage fluctuations, harmonic distortion, and power outages can damage equipment, disrupt production, and compromise safety. Three Phase Tech Services delivers comprehensive secure power solutions covering power quality mitigation, backup power systems, and power quality analysis. Facility managers, operations teams, and maintenance engineers rely on these solutions to protect sensitive equipment, maintain operational continuity, and reduce energy costs.
Why This Service Matters
Modern facilities depend on reliable power for critical processes, data systems, and safety equipment. Power quality issues and supply interruptions create risks ranging from minor inconvenience to significant financial losses and safety hazards.
Problems Addressed
- Harmonic distortion causing equipment overheating and premature failure
- Low power factor resulting in utility penalties and increased energy costs
- Voltage sags and swells affecting sensitive electronic equipment
- Power outages disrupting critical operations and data systems
- Reactive power imbalance reducing system efficiency
- Voltage instability affecting motor performance and process control
Potential Outcomes
- Reduced harmonic distortion meeting IEEE 519 compliance levels
- Improved power factor eliminating utility penalties
- Stable voltage supply protecting sensitive equipment
- Continuous power availability for critical operations
- Lower energy costs through improved system efficiency
- Extended equipment life through cleaner power supply
Secured Power Solutions
Specialized services address different aspects of power quality and supply reliability. Each service can be delivered independently or combined into a comprehensive power protection program.
Power Quality Mitigation Solutions
Design, supply, installation, and commissioning of active harmonic filters (AHF), static VAR generators (SVG), capacitor banks, and other power conditioning equipment to correct power quality issues.
Backup Power Solutions (UPS etc.)
Design, installation, and maintenance of uninterruptible power supply (UPS) systems, battery banks, and emergency power solutions to ensure continuous power for critical loads.
Power Quality Analysis
Comprehensive measurement and analysis of power quality parameters including harmonics, power factor, voltage disturbances, and transients to identify issues and recommend solutions.
Segments We Serve
Retail
Healthcare
Hospitality
data centers
Manufacturing
Processing Industry
Facility Management
Water Treatment Plants
Power Quality Analysis Services & Application Areas
Measurement and Monitoring
- Voltage and current waveform capture
- Harmonic spectrum analysis up to 50th order
- Power factor measurement
- Voltage sag, swell, and interruption logging
- Transient capture and analysis
- Flicker measurement
Analysis and Reporting
- Comparison against IEEE 519 and IEC 61000 standards
- Identification of harmonic sources
- Power factor penalty calculations
- Equipment impact assessment
- Trend analysis and pattern identification
- Root cause analysis for power quality events
Recommendations
- Mitigation equipment sizing and selection
- Cost-benefit analysis for proposed solutions
- Implementation priorities and sequencing
- Expected improvements and ROI projections
Data Centers and IT Facilities
- Server room power protection
- Network equipment backup
- Cooling system power quality
- Redundant power architectures
Healthcare Facilities
- Medical imaging equipment protection
- Operating room power quality
- Life safety system backup
- Laboratory equipment power conditioning
Manufacturing and Process Industries
- VFD and motor drive applications
- Sensitive process control equipment
- Welding and arc furnace installations
- CNC machine power quality
Commercial Buildings
- Elevator and HVAC system power
- Lighting system harmonics
- Tenant IT load protection
- Building management system backup
Critical Infrastructure
- Telecommunications facilities
- Transportation systems
- Water treatment plants
- Emergency services
How Engagement Works
Three engagement models accommodate different requirements.
Duration: 2 to 4 weeks depending on scope
Duration: 6 to 16 weeks depending on scope
Frequency: Quarterly, semi-annual, or annual service visits
Equipment and Brands
Solutions utilize equipment from leading manufacturers:
Power Quality Equipment
- Schneider Electric
- ABB
- Siemens
- Danfoss
- Schaffner
- Comsys
- Epcos/TDK
UPS Systems
- Schneider Electric (APC)
- Eaton
- Vertiv (Emerson)
- ABB
- Riello
- Socomec
- Delta
Measurement Instruments
- Fluke
- Hioki
- Dranetz
- AEMC
- Chauvin Arnoux
Frequently Asked Questions
What causes power quality problems?
Power quality issues typically result from non-linear loads such as variable frequency drives, UPS systems, LED lighting, computers, and electronic equipment. These loads draw non-sinusoidal currents that create harmonic distortion in the electrical system.
How do I know if my facility has power quality issues?
Common symptoms include equipment overheating, nuisance tripping of circuit breakers, transformer humming, capacitor failures, motor vibration, and unexplained equipment malfunctions. Power quality analysis can identify and quantify specific issues.
What is the difference between AHF and SVG?
Active harmonic filters (AHF) primarily address harmonic distortion by injecting compensating currents. Static VAR generators (SVG) primarily provide reactive power compensation for power factor correction. Some facilities require both technologies for comprehensive power quality improvement.
Do capacitor banks still make sense with harmonic issues?
Traditional capacitor banks can be problematic in harmonic-rich environments due to resonance risks. Detuned reactor systems or SVG technology are often better choices for facilities with significant non-linear loads.
What UPS topology is best for critical loads?
Online double-conversion UPS systems provide the highest level of protection by continuously conditioning power through the UPS regardless of utility conditions. This topology is recommended for sensitive IT equipment, medical devices, and critical process control systems.
How often should UPS batteries be replaced?
VRLA battery life typically ranges from 3 to 5 years depending on operating conditions. Regular battery testing helps identify degradation before failure. Lithium-ion batteries generally have longer service life but higher initial cost.
Can power quality issues affect my electricity bill?
Yes. Low power factor results in utility penalties in many jurisdictions. Additionally, harmonic distortion increases losses throughout the electrical system, resulting in higher energy consumption for the same useful work.
What standards apply to power quality?
Key standards include IEEE 519 for harmonic control, IEC 61000 series for electromagnetic compatibility, and EN 50160 for voltage characteristics. Specific requirements depend on utility interconnection agreements and local regulations.